ter Hürne - unique as life itself
             

Clips are decisive for the optical appearance

ter Hürne decor panels are quick and easy to install on the base construction. No special construction skills or tools are necessary. Depending on the type of profile, the panels are either screwed on directly, using the screws provided, or aligned and fixed with ter Hürne fixing clips.


Round profile with visible joint

Round profile with visible joint 10 mm with clip no. T3

Installation: Round profile with visible joint = clip no. T3

  • Paneel mit fester Feder in 12 mm Stärke
  • Deckfläche und Längskanten ohne Unterbrechung ummantelt
  • Deckbreite 188 mm
  • Befestigung:
    Klammer Nr. T3 bei 10 mm Sichtfuge
  • Mengenbedarf:
    100 Klammern für ca. 40 lfm Dekor-Paneele

clip no. T3

Round profile with no joint

Round profile with no joint with clip no. 3

Installation: Round profile with no joint with clip no. 3

  • Panel with fixed tongue, 12 mm wide
  • Continuous decor covering over surface and long edges
  • Cover width 178 mm
  • Installation:
    clip no. 3 / Visible joint of 0 mm
  • Requisition:
    100 clips for about 40 lm panels

clip no. 3



Soft profile with no joint

Soft profile with no joint with clip no. 3

Montage: Soft profile with no joint = clip no. 3

  • Panel with fixed tongue, 12 mm wide
  • Continuous decor covering over surface and long edges
  • Cover width 220 mm
  • Installation:
    clip no. 3
  • Requisition:
    100 clips for about 40 lm panels

clip no. 3

Soft profile with no joint

Soft profile with no joint with special screws

Installation: ter Hürne Spax special screws 3 x 25 mm for Soft profile panel

  • Panel with fixed tongue, 12 mm wide
  • Continuous decor covering over surface and long edges
  • Cover width 220 mm
  • Installation:
    ter Hürne Spax special screws 3 x 25 mm
  • Mengenbedarf:
    100 screws for about 40 lm panels

ter Hürne Spax special screws 3 x 25 mm


Use original ter Hürne accessories for the assembly



Framework

For the installation advice for decor panels click on the picture (no. 8).

Use standard planed and even battens with a maximum wood moisture content of 10% for the framework. The minimum cross section should be 25x50 mm to ensure stability and enable the possible installation of lighting systems.

  • Follow the installation plan to determine the spacing of the battens.
  • Batten spacing: 312-500 mm
  • The framework must be level (max. 2 mm/m deviation permitted).
  • Levelling compound or material can be used to eliminate uneven sections of the ceiling or wall. Test unevenness with the help of a straight edge, spirit level or plumb line.

Ask your dealer which supporting structures are available!